Sample concentrator LB-21SC

Sample concentrator LB-21SC

Sample Concentrators LB-21SC are microprocessor controlled units that accelerate the concentration of multiple samples in a fast and convenient way. Available with single and double block heaters, these units blow each sample independently and a large number of samples all at once.

Get Quote Download Catalog

Specifications

Number of Blocks 2
Nitrogen gas flow rate 15 L / min
Nitrogen gas pressure 0.1 Mpa
Heat up time ≤ 15 mins (25 °C to 160 °C)
Power 500 W
Needle length 150 mm
Temperature control range RT 5 °C to 160 °C
Time range 1 min to 99 hrs and 59 mins
Temperature uniformity ≤ ± 0.5 °C
40 °C Temperature accuracy ± 0.5 °C
120 °C Temperature accuracy ± 1 °C
Voltage AC 220 V, 50 Hz
AC 110 V, 60 Hz
Dimensions (W × D × H) 260 × 220 × 475 mm
Weight 7.5 kgs

Features

  • High precision temperature control
  • Adjustable airflow amount
  • High purity Aluminium heat conductor
  • Gas needle controlled independently

Applications

Used in drug screening, sample preparation analysis, hormone assays, chromatographic analysis, scintillation counting, commodity inspection, etc.

Optional Blocks

Block typeBlock diameterBlock capacity
B0110 mm12
B0212 mm12
B0313 mm12
B0415 mm12
B0516 mm12
B0619 mm12
B0720 mm12

Get Quote

Sample Concentrator

Number of Blocks 2
Nitrogen gas flow rate 330 ml / min
Nitrogen gas pressure 33 kPa to 69 kPa
Heat up time ≤ 30 mins (40 °C to 150 °C)
Number of Blocks 2
Nitrogen Gas Flow Rate 15L/min
Nitrogen Gas Pressure 0.1Mpa
Temperature Range 0 °C to 160 °C
Number of Blocks 1
Nitrogen Gas Flow Rate 15L/min
Nitrogen Gas Pressure 0.02Mpa (Gas needle≤16pcs)
0.05Mpa (Gas needle>16pcs)
Temperature Range 0 °C to 160 °C
Number of Blocks 1
Nitrogen gas flow rate 330 ml / min
Nitrogen gas pressure 33 kPa to 69 kPa
Needle length 80 mm
Number of Blocks 1
Nitrogen Gas Flow Rate 15L/min
Nitrogen Gas Pressure 0.1Mpa
Temperature Range 0 °C to 160 °C
Number of Blocks 2
Nitrogen Gas Flow Rate 23L/min
Nitrogen Gas Pressure 0.02Mpa (Gas needle≤16pcs)
0.05Mpa (Gas needle>16pcs)
Temperature Range 0 °C to 160 °C
Number of Blocks 1
Nitrogen gas flow rate 15 L / min
Nitrogen gas pressure 0.1 MPa
Needle length 150 mm
Number of Blocks 1
Nitrogen Gas Flow Rate 15L/min
Nitrogen Gas Pressure 0.1Mpa
Needle Length 150 mm
Number of Blocks 1
Nitrogen gas flow rate 15 L / min
Nitrogen gas pressure 0.02 MPa (Gas needle ≤ 16 pcs)
0.05 MPa (Gas needle > 16 pcs)
Needle length 150 mm
Number of Blocks 2
Nitrogen gas flow rate 15 L / min
Nitrogen gas pressure 0.02 MPa (Gas needle ≤ 16 pcs)
0.05 MPa (Gas needle > 16 pcs)
Heat up time ≤ 15 mins (25 °C to 160 °C)
Number of Blocks 1
Nitrogen gas flow rate 330 ml / min
Nitrogen gas pressure 33 kPa to 69 kPa
Needle length 150 mm
Nitrogen gas flow rate 15 L / min
Nitrogen gas pressure 200 kPa
Tube size 10 to 29 mm (liquid volume 1 ml to 50 ml)
Sample position 12 positions
Number of Blocks 1
Nitrogen Gas Flow Rate 15L/min
Nitrogen Gas Pressure 0.05 Mpa
Temperature Control Range RT+5℃ to 160℃
×

Ask Quote

Copyright © Labotronics Scientific 2026