Fixed Volume Micro Pipette LB-16FVP

Fixed Volume Micro Pipette LB-16FVP

Fixed Volume Micro Pipette LB-16FVP is lightweight and durable offering a pipetting volume of 200 µL. This pipette can be autoclaved at 121℃ temperature for effective sterilization. It employs a spring-loaded design for easy maintenance of the tip cones. Tip cones of the pipette are chemical-resistant with high sealing performance. Designed with a precision volume locking mechanism for accurate and reliable results.

Get Quote Download Catalog

Specifications

Volume Range 200 μL
Test Volume 200 μL
Accuracy Error ± 0.8 μL
± 0.4 %
Precision Error ± 0.4 μL
± 0.2 %

Features

  • Equipped with digital display
  • Easy calibration and maintenance
  • Incorporates a low-force tip ejector
  • Offers finger support for user comfort
  • Smooth plunger mechanism for controlled liquid handling
  • Adheres to ISO 8655 standards

Applications

Fixed Volume Micro Pipette is used for accurate and consistent dispensing of a specific, predetermined volume of liquid within the microliter range. It is employed in various fields like molecular biology, clinical diagnostics, biochemistry, and in chemical analysis.
Fixed Volume Micro Pipette LB-16FVP Banner
Fixed Volume Micro Pipette LB-16FVP Banner

Get Quote

Fixed Volume Micro Pipette

Volume Range 25 μL
Test Volume 25 μL
Accuracy Error ± 0.125 μL
± 0.5 %
Precision Error ± 0.075 μL
± 0.3 %
Volume Range 10 μL
Test Volume 10 μL
Accuracy Error ± 0.08 μL
± 0.8 %
Precision Error ± 0.08 μL
± 0.8 %
Volume Range 50 μL
Test Volume 50 μL
Accuracy Error ± 0.25 μL
± 0.5 %
Precision Error ± 0.15 μL
± 0.3 %
Volume Range 2000 μL
Test Volume 2000 μL
Accuracy Error ± 6.0 μL
± 0.3 %
Precision Error ± 3.0 μL
± 0.15 %
Volume Range 5000 μL
Test Volume 5000 μL
Accuracy Error ± 15 μL
± 0.3 %
Precision Error ± 7.5 μL
± 0.15 %
Volume Range 20 μL
Test Volume 20 μL
Accuracy Error ± 0.12 μL
± 0.6 %
Precision Error ± 0.1 μL
± 0.5 %
Volume Range 5 μL
Test Volume 5 μL
Accuracy Error ± 0.0625μL
± 1.3 %
Precision Error ± 0.06 μL
± 1.2 %
Volume Range 100 μL
Test Volume 100 μL
Accuracy Error ± 0.5 μL
± 0.5 %
Precision Error ± 0.3 μL
± 0.3 %
Volume Range 1000 μL
Test Volume 1000 μL
Accuracy Error ± 3.0 μL
± 0.3 %
Precision Error ± 2.0 μL
± 0.2 %
Volume Range 250 μL
Test Volume 250 μL
Accuracy Error ± 1.0 μL
± 0.4 %
Precision Error ± 0.5 μL
± 0.2 %
Volume Range 500 μL
Test Volume 500 μL
Accuracy Error ± 1.5 μL
± 0.3 %
Precision Error ± 1.0 μL
± 0.2 %
×

Ask Quote