Dry Bath Incubator LB-66DBI operates within a temperature range of -10 °C to 100 °C for precise sample incubation. It features microprocessor control for accurate and stable temperature regulation. It uses high-purity aluminium blocks, ensuring efficient and uniform heat conduction. Our dry bath incubator is equipped with a clear LCD screen, providing real-time display of temperature and time settings for easy monitoring.
Get Quote Download CatalogSpecifications
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT-30 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Temperature Display Accuracy | 0.1℃ |
| Block Temperature Uniformity | ≤ ± 0.3°C |
| Heating Rate | ≤10min( 25℃ to 100℃) |
| Cooling Rate | ≤10min (from 100℃ to 25℃) ≤25 min (from RT to RT - 30 °C) |
| Time Range | 1 min to 99 hrs 59 mins / ∞ (continuous operation) |
| Power Consumption | 150 W |
| Power Supply | AC100 to 240V 50/60Hz |
| Dimensions (W × D × H) | 260 × 195 × 150 mm |
| Weight | 4.5 kg |
Features
Interchangeable blocks
Audible buzzer alerts
Integrated thermal protection
Adjustable temperature calibration
Internal error detection system
Applications
Dry Bath Incubator LB-66DBI is widely used in research labs, clinical laboratories, and pharmaceutical facilities. It supports sample incubation, enzyme reactions, DNA denaturation, and other temperature-sensitive applications.
Block Selection
Block No. | Block Capacity |
B1 | 0.2 ml × 96 |
B2 | 0.5 ml × 54 |
B3 | 1.5 ml × 35 |
B4 | 2.0 ml × 35 |
B5 | 0.5 ml × 15 + 1.5 ml × 20 |
B6 | 0.2 ml Elisa plate × 96 |
B7 | 5 ml × 24 |
B8 | 10 ml × 15 |
B9 | 15 ml × 12 |
B10 | 50 ml (round bottom) × 6 |
B11 | 50 ml (cone-shape bottom) × 6 |
Frequently asked questions For
1. What types of tubes or containers are compatible with the Dry Bath Incubator LB-66DBI?
Our Dry Bath Incubator LB-66DBI supports multiple block configurations, accommodating tubes from 0.2 ml to 50 ml, including conical, round-bottom, and Elisa plates.
2. Can the Dry Bath Incubator LB-66DBI be operated continuously?
Yes, the Dry Bath Incubator LB-66DBI supports both continuous and timed operations. This flexibility allows users to maintain stable temperatures for long procedures or run short, time-based protocols efficiently.
3. What laboratory applications can the Dry Bath Incubator LB-66DBI be used for?
Our Dry Bath Incubator LB-66DBI is used for sample incubation, enzyme reactions, DNA denaturation, and other temperature-controlled processes. It is widely used in research laboratories, clinical labs, and pharmaceutical facilities for reliable and consistent thermal performance.
4. Does the Dry Bath Incubator LB-66DBI include any alert system?
Yes, the Dry Bath Incubator LB-66DBI includes an audible buzzer that provides alerts when incubation time ends or when any irregularity is detected during operation.
Still have questions?
If you cannot find answer to your question in our FAQ, you can always
contact us. We will answer shortly!
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 5 °C to 130 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ± 1°C (at 120°C) |
| Temperature Display Accuracy | 0.1℃ |
| Block capacity | 1 block |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40 °C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 110 °C |
| Temperature Control Range | RT +5 °C to 110 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Block Capacity | 1 block |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT +5 °C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Block Capacity | 1 block |
| Temperature Range | -10 °C to 100 °C |
| Temperature Control Range | RT -25°C to 100 °C |
| Heating Lid Temperature Range | OFF to 10℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C |
| Block Capacity | 2 blocks |
| Temperature Range | 5 to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
| Block capacity | 2 blocks |
| Temperature Range | 5 °C to 160 °C |
| Temperature Accuracy | ± 0.5°C (at 40°C) ±1°C (at 120 °C) |
| Temperature Display Accuracy | 0.1℃ |
| Block Capacity | 4 blocks |
| Temperature Range | 0 °C to 100 °C |
| Temperature Control Range | RT+5°C to 100 °C |
| Temperature Accuracy | ≤ ± 0.3°C (at 37°C) |
| Block Capacity | 1 block |
| Temperature Range | 5 ℃ to 150 ℃ |
| Temperature Control Range | R.T. +5 ℃ to 150 ℃ |
| Temperature Display Accuracy | 0.1℃ |
Address: Labotronics Scientific. 1007 N Orange St.,
Wilmington, DE 19801, USA
Mail: info@labotronics.eu
WhatsApp: +1 579 401 0534