Differential thermal analyzer LB-10DTA

Differential thermal analyzer LB-10DTA

Differential thermal analyzer LB-10DTA determines the inner heat transition relating to temperature and heat flow with temperature range of RT to 1150 ℃. Equipped with 7-inch touch screen display for visualization of the technical parameters and USB communication interface for transfer of the data. Designed with indirect conduction method for maintaining high uniformity and stability, it has self-recovery connection function for accurate and reliable results.

Get Quote Download Catalog

Specifications

Temperature range RT to 1150 ℃
Heating rate 0.1 to 80℃/min
Temperature resolution 0.001 ℃
Temperature fluctuations ± 0.001 ℃
Temperature repeatability ±0.1 ℃
Constant temperature time Program setting ≤ 24 h
DSC range 0 to ± 60 mW
DSC noise 0.01 μW
DSC resolution 0.01 μW
DSC accuracy 0.01 mW
Atmosphere control gas Nitrogen, Oxygen (instrument switch automatically)
Gas flow rate 0 to 300 mL/min
Gas pressure 0.2 MPa
Control Mode Rising temperature, constant temperature (Fully automatic)
Curve scanning Rising scan
Gas flow control Built-in digital flow meter & Software control, automatic
Display 24-bit 7 inches LCD touch screen display
Data interface Standard USB connector
Parameter standard With standard material, with calibration function, the user may correct temperature and heat enthalpy
Software 4 in 1 operating software, can switch to DSC, DTA, TGA, STA
Thermocouples Total 3 sets of thermocouples for test sample temperature, test furnace temperature, Test internal ambient temperature
Cooling device Air cool
Power AC220V/50Hz

Features

  • 7-inch touch screen display for visualization of technical parameters
  • Metal furnace body structure for better baseline and higher precision
  • Indirect conduction method for heating with high uniformity and stability
  • Reduces pulse radiation for effective operation of the analyzer
  • USB communication interface for simplified exchange of the data
  • Excellent adaptability, consistent and uninterrupted communication
  • Supports self-recovery connection function, reliable operation
  • Automatic switching between two channels of atmospheric flow
  • Rapid switchover and stability for quick and accurate operation
  • Protective gas input is also added at the same time
  • Software is user-friendly and straightforward

Applications

Differential thermal analyzer is used for determining the inner heat transition across analytical chemistry, metallurgy, construction fields research, pharmaceutical industry, food, environmental and testing.

Get Quote

×

Ask Quote

Copyright © Labotronics Scientific 2026